- Compute capacity
- 32 cores / node
- 4.7 GHz; AIX or Linux HPC
- Machine type and model
- 9125-F2A
- Match the system label
- Processor
- 32 cores per node at 4.7 GHz
- Match the processor feature and activation
- Memory
- 32 to 256 GB DDR2 per node
- Match the installed memory features
On this page
Power 6 575 9125-F2A specifications
| Specification | Configuration |
|---|---|
| Machine type and model | 9125-F2A |
| Chassis | Water-cooled 2U node in a dedicated 24-inch frame |
| Processor capacity | 32 cores per node at 4.7 GHz |
| Memory | 32 to 256 GB DDR2 per node |
| Storage and I/O | Two internal SFF SAS positions; four PCIe slots per node |
| Operating environments | AIX or Linux |
Power 6 575 9125-F2A processor options
| Feature or arrangement | Cores | Clock | Configuration detail |
|---|---|---|---|
| 7298 | 32 per node | 4.7 GHz | POWER6 HPC compute node; up to fourteen nodes in the documented frame |
575 configuration and upgrade limits
- The 575 is an AIX or Linux HPC node. The Midland-hosted facts sheet explicitly excludes IBM i and gives no applicable commercial rPerf rating.
- The 32-core and 256 GB ceilings are per node. The frame and cluster contain multiple nodes and must be inventoried separately.
- IBM lists service DIMM 87H3621 as 8 MG DIMM. The unit label is ambiguous, so its capacity is not treated as a confirmed 8 GB ordering specification.
- The optional I/O assembly determines PCI and drawer-attachment capability. Water-cooled node service and bulk power need their own installation plan.
575 workload sizing
The family facts sheet marks commercial AIX rPerf as not applicable to the 575. Size the replacement from the HPC jobs, memory demand, communication pattern, and storage throughput instead.
Power 6 575 service and replacement planning
We can help source repair parts or compare a newer system for this installed model. Include the serial number so we can check the support options available for your configuration.
Compare the Power 10 models and Power 11 models for the next system. We size the replacement around your software and active workload, then check which storage and I/O can move with it.
Room and upgrade requirements
Check the installed system before choosing a part or planning a move.
- Identify the system. Send the complete 9125-F2A machine type and model, serial number, and active processor features.
- Document the installation. Record the 24-inch frame, water cooling units, supply and return connections, water quality, bulk-power assemblies, floor loading, and service access. Use the complete cluster load for facility planning.
- Record the hardware. List DIMM features, drive carriers, storage controllers, and expansion drawers. Include network and Fibre Channel adapters with their slot locations.
- Define the change. Tell us whether you need a repair, more capacity, a relocation, or a replacement quote. Include the operating-system release and application requirements.
575 software and management check
Preserve the AIX or Linux release, cluster fabric, job scheduler, storage layout, and application libraries. Review the firmware and HMC requirements and the documented ECA845 procedure with the service provider before a firmware change.
575 technical references
Hardware specifications and feature context: Our catalog reference 1 · IBM technical reference 2 · IBM technical reference 3.
IBM Power 6 575 9125-F2A feature and configuration details
Use these entries to match the chart’s identifiers to their exact configuration. Keep each performance figure with its stated core count, threading mode and model scope.
7298 ... 9125-F2A
575 processor configurations
- Cores
- 32 per node
- Clock
- 4.7 GHz
- Configuration detail
- POWER6 HPC compute node; up to fourteen nodes in the documented frame
Understand this configuration and identifier before matching a replacement. Send the complete model and 7298 entry with your configuration or parts request.
Parts for this 575 model
Use these 9125-F2A memory, storage, and adapter identifiers for your repair or upgrade quote. Feature codes and service part numbers identify different items; include the labels from the installed system.
Memory
Match these documented identifiers to the installed 9125-F2A configuration.
| Product | Description | Part numbers | Feature codes | Model note |
|---|---|---|---|---|
| DIMM service part; capacity label requires confirmation | DIMM service part; capacity label requires confirmation | 87H3621 | IBM service table says 8 MG DIMM. Send the installed label before ordering. |
DIMM service part; capacity label requires confirmation for 9125-F2A
DIMM service part; capacity label requires confirmation
- Part numbers
- 87H3621
IBM service table says 8 MG DIMM. Send the installed label before ordering.
Match this memory option to the installed module arrangement. The capacity can describe one module or a complete kit; the description and model note retain that distinction.
Confirm the installed carrier, connector, firmware, and operating-system support before ordering.
Disk
Match these documented identifiers to the installed 9125-F2A configuration.
| Product | Description | Part numbers | Feature codes | Model note |
|---|---|---|---|---|
| SAS controller | SAS controller | 44V4404 | ||
| RAID controller | RAID controller | 44V4203 | ||
| SAS cables | SAS cables, 1, 3, or 6 meters | 44V4147 / 44V4148 / 44V4149 | Match the storage topology and connector type. |
SAS controller for 9125-F2A
SAS controller
- Part numbers
- 44V4404
Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.
RAID controller for 9125-F2A
RAID controller
- Part numbers
- 44V4203
Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.
SAS cables for 9125-F2A
SAS cables, 1, 3, or 6 meters
- Part numbers
- 44V4147 / 44V4148 / 44V4149
Match the storage topology and connector type.
Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.
Confirm the installed carrier, connector, firmware, and operating-system support before ordering.
Adapters
Match these documented identifiers to the installed 9125-F2A configuration.
| Product | Description | Part numbers | Feature codes | Model note |
|---|---|---|---|---|
| I/O assembly with PCI and I/O drawer attachment | I/O assembly with PCI and I/O drawer attachment | 45D4595 | ||
| I/O assembly without PCI capability | I/O assembly without PCI capability | 45D4597 | ||
| Left and right PCI risers | Left and right PCI risers | 45D0965 / 45D0971 |
I/O assembly with PCI and I/O drawer attachment for 9125-F2A
I/O assembly with PCI and I/O drawer attachment
- Part numbers
- 45D4595
Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.
I/O assembly without PCI capability for 9125-F2A
I/O assembly without PCI capability
- Part numbers
- 45D4597
Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.
Left and right PCI risers for 9125-F2A
Left and right PCI risers
- Part numbers
- 45D0965 / 45D0971
Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.
Confirm the installed carrier, connector, firmware, and operating-system support before ordering.
Request 575 configuration and upgrade help
Send the 9125-F2A serial number and installed features. We can match compatible parts and prepare a repair, upgrade, or replacement quote for your workload.
Discuss your 575 with Midland