FlashSystem 5100 specifications
FlashSystem 5100 enclosure and performance specifications| Specification | Model detail |
|---|
| Machine type and model | 2077-4H4; 2078-4H4; 2078-UHB |
|---|
| Control enclosure | 2U |
|---|
| Internal drive positions | 24 NVMe |
|---|
| System cache / memory | 64 / 192 / 576 GB |
|---|
| Published IOPS | Up to 900,000 |
|---|
| Published bandwidth | 15 Gb/s as published |
|---|
| Capacity context | Drive and RAID dependent |
|---|
Published maxima describe specific test conditions. Application results depend on the drive population and RAID layout as well as block size, read/write mix and host connections.
FlashSystem 5100 drive choices and capacity
FlashSystem 5100 storage media| Drive class | Supported source context |
|---|
| FCM1 | AES1 to AES3; 4.8 TB through 19.2 TB |
|---|
| FCM2 | AES5 to AES8; 4.8 TB through 38.4 TB |
|---|
| Industry NVMe | AET1 to AET5; 800 GB through 15.36 TB |
|---|
| SCM | AETA / AETB / AETE / AETF, software-dependent |
|---|
Raw capacity is the installed media total before RAID and reserves. Usable capacity is what remains for data; effective capacity also assumes compression or other data reduction.
FlashSystem 5100 host connectivity
FlashSystem 5100 host and expansion connections| Connection | Configuration |
|---|
| Standard | Eight 10 Gb Ethernet ports on the family page |
|---|
| Options | 16 / 32 Gb FC with FC-NVMe; 25 Gb Ethernet iSCSI and iSER |
|---|
FlashSystem 5100 expansion and scale
FlashSystem 5100 expansion scope| Option | Model or limit |
|---|
| LFF / SFF / HD | 2077 or 2078 12G, 24G and 92G enclosure families |
|---|
| Scale | 760 drives per system; 1,520 clustered in the family overview |
|---|
FlashSystem 5100 detailed hardware and feature tables
5100 2077-4H4 control enclosure specifications
5100 2077-4H4 control enclosure specifications| Specification | IBM FlashSystem 5100 2077-4H4 |
|---|
| IBM Machine Type / Model | 2077-4H4 |
|---|
| Product Family | IBM FlashSystem 5100 |
|---|
| Form Factor | 2U rack-mount control enclosure |
|---|
| Internal Drive Bays | 24 × 2.5-inch NVMe-capable bays |
|---|
| Internal Storage Types | IBM FlashCore Modules, industry-standard NVMe SSDs and Storage Class Memory |
|---|
| Expansion Interface | 12 Gb SAS |
|---|
| Expansion Enclosures | 2077-12G, 2077-24G and 2077-92G |
|---|
| Host Connectivity | 16/32 Gb Fibre Channel and 10/25 Gb Ethernet depending on installed adapters |
|---|
| Protocols | Fibre Channel, FC-NVMe, iSCSI, iSER where supported |
|---|
| Storage Software | IBM Storage Virtualize / Spectrum Virtualize |
|---|
| RAID | Distributed RAID 5, Distributed RAID 6, RAID 1 and RAID 10 depending on configuration |
|---|
| Maximum Drive Count | Up to 760 drives per system and 1,520 in a clustered configuration at supported software levels |
|---|
5100 model and utility-enclosure identities
5100 model and utility-enclosure identities| Machine Type / Model | Description |
|---|
| 2077-4H4 | FlashSystem 5100 NVMe control enclosure |
|---|
| 2078-4H4 | Corresponding FlashSystem 5100 NVMe control enclosure |
|---|
| 2078-UHB | FlashSystem 5100 utility-model NVMe control enclosure |
|---|
| 2077-424 / 2078-424 | Earlier Storwize V5100 designation corresponding to the FlashSystem 5100 architecture |
|---|
| 2077-AF4 / 2078-AF4 | All-flash V5100-family configurations |
|---|
5100 FCM2 ordering features and service parts
5100 FCM2 ordering features and service parts| Feature Code | Capacity | Primary IBM FRU | Additional IBM FCM2 Part |
|---|
| AES5 | 4.8TB | 02YC416 | 03GH469 |
|---|
| AES6 | 9.6TB | 02YC417 | 03GH470 |
|---|
| AES7 | 19.2TB | 02YC418 | 03GH471 |
|---|
| AES8 | 38.4TB | 02YC419 | 03GH472 |
|---|
5100 industry-standard NVMe drives
5100 industry-standard NVMe drives| Feature Code | Capacity | IBM FRU |
|---|
| AET1 | 800GB | 01YM585 |
|---|
| AET2 | 1.92TB | 01YM586 |
|---|
| AET3 | 3.84TB | 01YM587 |
|---|
| AET4 | 7.68TB | 01YM588 |
|---|
| AET5 | 15.36TB | 01YM589 |
|---|
5100 Storage Class Memory options
5100 Storage Class Memory options| Feature Code | Capacity | IBM FRU |
|---|
| AETA | 375GB | 02PX477 |
|---|
| AETB | 750GB | 02PX478 |
|---|
| AETE | 800GB | 02PX482 |
|---|
| AETF | 1.6TB | 02PX483 |
|---|
5100 SAS expansion models
5100 SAS expansion models| Model | Description | Drive Bays | Form Factor |
|---|
| 2077-12G | FlashSystem 5100 LFF SAS expansion enclosure | 12 | 2U / LFF |
|---|
| 2077-24G | FlashSystem 5100 SFF SAS expansion enclosure | 24 | 2U / SFF |
|---|
| 2077-92G | FlashSystem 5100 high-density SAS expansion enclosure | 92 | 5U high-density |
|---|
| 2077-12F | Earlier compatible LFF expansion enclosure | 12 | 2U / LFF |
|---|
| 2077-24F | Earlier compatible SFF expansion enclosure | 24 | 2U / SFF |
|---|
| 2077-92F | Earlier compatible high-density expansion enclosure | 92 | 5U |
|---|
5100 internal NVMe versus external SAS storage
5100 internal NVMe versus external SAS storage| Characteristic | Internal 2077-4H4 Storage | External Expansion Storage |
|---|
| Interface | NVMe / PCIe | 12 Gb SAS |
|---|
| FlashCore Modules | Yes | No |
|---|
| Industry NVMe SSD | Yes | No |
|---|
| Storage Class Memory | Yes | No |
|---|
| SAS SSD | No | Yes |
|---|
| 10K / 15K SAS HDD | No | Yes |
|---|
| Nearline SAS HDD | No | Yes |
|---|
| Primary Use | Low-latency performance tier | Capacity expansion and hybrid tiering |
|---|
FlashSystem 5100 configuration limits and source differences
- The family page prints bandwidth as 15 Gb/s. We retain that unit pending confirmation instead of silently changing it to GB/s.
- The family heading uses 2077-4F4 while the dedicated product is 2077-4H4. Match the installed model label before ordering.
- AES, ADS, AGS and AHS identify different ordering contexts even when a service part appears across families.
FlashSystem 5100 software and IBM i attachment
We check the installed IBM Storage Virtualize or Spectrum Virtualize level against the proposed drives and adapters. Features such as replication, encryption and snapshots depend on the model, software level and entitlements.
For IBM i, send the Power model, IBM i release and host adapter details. We check direct or switched attachment and the supported protocol in the IBM System Storage Interoperation Center before finalizing the configuration.
FlashSystem 5100 data services and availability
- Hardware-assisted compression in both eight-core node canisters.
- External storage virtualization, FlashCopy and supported replication functions.
Room and upgrade requirements for FlashSystem 5100
- Identify the installation. Send the complete machine type, serial number and installed software level.
- Record capacity and workload. Include installed drive types, RAID layout and current usable space with peak IOPS and latency.
- Check rack and power. Record rail depth, service clearance and the existing outlet and PDU connections; include every expansion shelf.
- Plan attachment and migration. Include host adapters, switch models and optics with the available migration window.
FlashSystem 5100 technical references
FlashSystem 5100 product specifications and identifiers ... FlashSystem family specifications.
Parts and options for FlashSystem 5100
Match each option to the installed enclosure and software. An order feature, drive-model identifier and service FRU have different roles; the source context below stays with each number.
Memory
Published options for this model; send the installed identifier with a parts request.
FlashSystem 5100 memory options
| Product |
Description |
Part numbers |
Feature codes |
Model note |
| System cache |
64 GB base; 192 GB or 576 GB upgrade configurations |
|
|
|
Disk
Published options for this model; send the installed identifier with a parts request.
FlashSystem 5100 disk options
| Product |
Description |
Part numbers |
Feature codes |
Model note |
| FCM1 |
4.8 TB |
01YM582 |
AES1 |
|
| FCM2 |
19.2 TB |
02YC418 |
AES7 |
|
| FCM2 |
38.4 TB |
02YC419 |
AES8 |
|
| NVMe SSD |
1.92 TB |
01YM586 |
AET2 |
|
Adapters
Published options for this model; send the installed identifier with a parts request.
FlashSystem 5100 adapters options
| Product |
Description |
Part numbers |
Feature codes |
Model note |
| Fibre Channel |
16 / 32 Gb FC and supported FC-NVMe |
|
|
|
| Ethernet |
25 Gb iSCSI / iSER option |
|
|
|
| SAS expansion |
12 Gb attachment for supported external shelves |
|
|
|
Get a FlashSystem 5100 configuration or parts quote
Send us your installed model and the capacity or repair you need. We can match the controller, media and connections before quoting the complete configuration.
Request FlashSystem 5100 help