- Published bandwidth
- Up to 86 GB/s
- See the stated source and test context.
- Published IOPS
- Up to 6.3 million
- Control enclosure
- 2U
- 32 NVMe
- System cache
- 1.5 TB to 3 TB
On this FlashSystem 9600 page
FlashSystem 9600 specifications
| Specification | Model detail |
|---|---|
| Machine type and model | 5078-A40 |
| Control enclosure | 2U |
| Internal drive positions | 32 NVMe |
| System cache / memory | 1.5 TB to 3 TB |
| Published IOPS | Up to 6.3 million |
| Published bandwidth | Up to 86 GB/s |
| Capacity context | Up to 11.8 PBe, assumptions apply |
Published maxima describe specific test conditions. Application results depend on the drive population and RAID layout as well as block size, read/write mix and host connections.
FlashSystem 9600 drive choices and capacity
| Drive class | Supported source context |
|---|---|
| FCM5 | ADSJ / ADSK / ADSL / ADSM / ADSN; 6.6 TB through 105.6 TB |
| Standard NVMe | ADTH / ADTJ / ADTK; 1.92 TB through 7.68 TB |
| Enclosure | 5078-A40 control enclosure, part 03LG971 |
Raw capacity is the installed media total before RAID and reserves. Usable capacity is what remains for data; effective capacity also assumes compression or other data reduction.
FlashSystem 9600 host connectivity
| Connection | Configuration |
|---|---|
| Fibre Channel | 32 / 64 Gb FC and FC-NVMe |
| Ethernet | 25 / 10 Gb or 100 / 40 Gb iSCSI / NVMe/TCP |
| Maximum I/O | Thirty-two ports |
FlashSystem 9600 expansion and scale
| Option | Model or limit |
|---|---|
| FlashSystem Grid | Up to 377 PB effective in the dedicated page |
| Physical expansion | Confirm supported attachment for the exact software level and proposed configuration |
FlashSystem 9600 configuration limits and source differences
- The current dedicated page gives 2U, 6.3 million IOPS and 86 GB/s. The broad overview gives 4U, 16 million IOPS and 200 GB/s. Both source contexts remain recorded; this page follows the dedicated 5078-A40 model.
- The source does not give a matching read-hit or read-miss label for 6.3 million IOPS, so it is not treated as an equivalent benchmark to either.
- The dedicated source prints a 5:11 data-reduction guarantee. We do not turn that ambiguous ratio into a quote guarantee.
- 11.8 PBe and 377 PB effective rely on data reduction. RAID-usable physical capacity must be calculated for the ordered drives.
FlashSystem 9600 software and IBM i attachment
We check the installed IBM Storage Virtualize or Spectrum Virtualize level against the proposed drives and adapters. Features such as replication, encryption and snapshots depend on the model, software level and entitlements.
For IBM i, send the Power model, IBM i release and host adapter details. We check direct or switched attachment and the supported protocol in the IBM System Storage Interoperation Center before finalizing the configuration.
FlashSystem 9600 data services and availability
- Storage Virtualize thin provisioning, snapshots and supported replication.
- FlashSystem Grid management and workload movement.
- FlashCore hardware analytics, supported Safeguarded Copy and Storage Insights monitoring.
Room and upgrade requirements for FlashSystem 9600
- Identify the installation. Send the complete machine type, serial number and installed software level.
- Record capacity and workload. Include installed drive types, RAID layout and current usable space with peak IOPS and latency.
- Check rack and power. Record rail depth, service clearance and the existing outlet and PDU connections; include every expansion shelf.
- Plan attachment and migration. Include host adapters, switch models and optics with the available migration window.
FlashSystem 9600 technical references
FlashSystem 9600 product specifications and identifiers ... FlashSystem family specifications.
IBM FlashSystem 9600 5078-A40 feature and configuration details
Use these entries to match the chart’s identifiers to their exact configuration. Keep each capacity, connection and scale limit with its stated enclosure, software and system scope.
Maximum I/O ... 5078-A40
FlashSystem 9600 host and expansion connections
- Configuration
- Thirty-two ports
Understand this configuration and identifier before matching a replacement. Send the complete model and Maximum I/O entry with your configuration or parts request.
Parts and options for FlashSystem 9600
Match each option to the installed enclosure and software. An order feature, drive-model identifier and service FRU have different roles; the source context below stays with each number.
Memory
Published options for this model; send the installed identifier with a parts request.
| Product | Description | Part numbers | Feature codes | Model note |
|---|---|---|---|---|
| Memory module | 128 GB module in the dedicated parts list | 078P8006 | Total supported system memory is 1.5 to 3 TB; match installed module layout. |
Memory module for 5078-A40
128 GB module in the dedicated parts list
- Part numbers
- 078P8006
Total supported system memory is 1.5 to 3 TB; match installed module layout.
Match this memory option to the installed module arrangement. The capacity can describe one module or a complete kit; the description and model note retain that distinction.
Disk
Published options for this model; send the installed identifier with a parts request.
| Product | Description | Part numbers | Feature codes | Model note |
|---|---|---|---|---|
| FCM5 Small | 6.6 TB | 03PM128 | ADSJ | |
| FCM5 Medium | 13.2 TB | 03PM131 | ADSK | |
| FCM5 Large | 26.4 TB | 03PM134 | ADSL | |
| FCM5 XL | 52.8 TB | 03PM137 | ADSM | |
| FCM5 XXL | 105.6 TB, 9600-only in the 5600 source | 03PM220 | ADSN | |
| Standard NVMe SSD | 7.68 TB | 03NK551 | ADTK |
FCM5 Small for 5078-A40
6.6 TB
- Part numbers
- 03PM128
- Feature codes
- ADSJ
Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.
FCM5 Medium for 5078-A40
13.2 TB
- Part numbers
- 03PM131
- Feature codes
- ADSK
Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.
FCM5 Large for 5078-A40
26.4 TB
- Part numbers
- 03PM134
- Feature codes
- ADSL
Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.
FCM5 XL for 5078-A40
52.8 TB
- Part numbers
- 03PM137
- Feature codes
- ADSM
Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.
FCM5 XXL for 5078-A40
105.6 TB, 9600-only in the 5600 source
- Part numbers
- 03PM220
- Feature codes
- ADSN
Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.
Standard NVMe SSD for 5078-A40
7.68 TB
- Part numbers
- 03NK551
- Feature codes
- ADTK
Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.
Adapters
Published options for this model; send the installed identifier with a parts request.
| Product | Description | Part numbers | Feature codes | Model note |
|---|---|---|---|---|
| Fibre Channel | 32 Gb quad-port | 03JK177 | ||
| Fibre Channel | 64 Gb quad-port | 03JK911 | ||
| Ethernet | 100 / 40 Gb dual-port | 03JN309 | ||
| Ethernet | 25 / 10 Gb quad-port | 03NK184 | ||
| Control enclosure | 5078-A40 | 03LG971 | ||
| Node canister | 5078-A40 source context | 03MT852 | ||
| Power supply | 5078-A40 source context | 03NK500 |
Fibre Channel for 5078-A40
32 Gb quad-port
- Part numbers
- 03JK177
Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.
Fibre Channel for 5078-A40
64 Gb quad-port
- Part numbers
- 03JK911
Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.
Ethernet for 5078-A40
100 / 40 Gb dual-port
- Part numbers
- 03JN309
Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.
Ethernet for 5078-A40
25 / 10 Gb quad-port
- Part numbers
- 03NK184
Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.
Control enclosure for 5078-A40
5078-A40
- Part numbers
- 03LG971
Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.
Node canister for 5078-A40
5078-A40 source context
- Part numbers
- 03MT852
Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.
Power supply for 5078-A40
5078-A40 source context
- Part numbers
- 03NK500
Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.
Get a FlashSystem 9600 configuration or parts quote
Send us your installed model and the capacity or repair you need. We can match the controller, media and connections before quoting the complete configuration.
Request FlashSystem 9600 help