AS400 to IBM Power 11 Partners
(888) 682-5335

IBM FlashSystem 9600

FlashSystem 9600 5078-A40 storage and upgrades

Bring large production workloads together on the 9600 with FCM5 and up to 3 TB of cache. We can size the thirty-two-bay system and match host connectivity to the workload you plan to move.

Published bandwidth
Up to 86 GB/s
See the stated source and test context.
Published IOPS
Up to 6.3 million
Control enclosure
2U
32 NVMe
System cache
1.5 TB to 3 TB
On this FlashSystem 9600 page

FlashSystem 9600 specifications

FlashSystem 9600 enclosure and performance specifications
SpecificationModel detail
Machine type and model5078-A40
Control enclosure2U
Internal drive positions32 NVMe
System cache / memory1.5 TB to 3 TB
Published IOPSUp to 6.3 million
Published bandwidthUp to 86 GB/s
Capacity contextUp to 11.8 PBe, assumptions apply

Published maxima describe specific test conditions. Application results depend on the drive population and RAID layout as well as block size, read/write mix and host connections.

FlashSystem 9600 drive choices and capacity

FlashSystem 9600 storage media
Drive classSupported source context
FCM5ADSJ / ADSK / ADSL / ADSM / ADSN; 6.6 TB through 105.6 TB
Standard NVMeADTH / ADTJ / ADTK; 1.92 TB through 7.68 TB
Enclosure5078-A40 control enclosure, part 03LG971

Raw capacity is the installed media total before RAID and reserves. Usable capacity is what remains for data; effective capacity also assumes compression or other data reduction.

FlashSystem 9600 host connectivity

FlashSystem 9600 host and expansion connections
ConnectionConfiguration
Fibre Channel32 / 64 Gb FC and FC-NVMe
Ethernet25 / 10 Gb or 100 / 40 Gb iSCSI / NVMe/TCP
Maximum I/OThirty-two ports

FlashSystem 9600 expansion and scale

FlashSystem 9600 expansion scope
OptionModel or limit
FlashSystem GridUp to 377 PB effective in the dedicated page
Physical expansionConfirm supported attachment for the exact software level and proposed configuration

FlashSystem 9600 configuration limits and source differences

  • The current dedicated page gives 2U, 6.3 million IOPS and 86 GB/s. The broad overview gives 4U, 16 million IOPS and 200 GB/s. Both source contexts remain recorded; this page follows the dedicated 5078-A40 model.
  • The source does not give a matching read-hit or read-miss label for 6.3 million IOPS, so it is not treated as an equivalent benchmark to either.
  • The dedicated source prints a 5:11 data-reduction guarantee. We do not turn that ambiguous ratio into a quote guarantee.
  • 11.8 PBe and 377 PB effective rely on data reduction. RAID-usable physical capacity must be calculated for the ordered drives.

FlashSystem 9600 software and IBM i attachment

We check the installed IBM Storage Virtualize or Spectrum Virtualize level against the proposed drives and adapters. Features such as replication, encryption and snapshots depend on the model, software level and entitlements.

For IBM i, send the Power model, IBM i release and host adapter details. We check direct or switched attachment and the supported protocol in the IBM System Storage Interoperation Center before finalizing the configuration.

FlashSystem 9600 data services and availability

  • Storage Virtualize thin provisioning, snapshots and supported replication.
  • FlashSystem Grid management and workload movement.
  • FlashCore hardware analytics, supported Safeguarded Copy and Storage Insights monitoring.

Room and upgrade requirements for FlashSystem 9600

  1. Identify the installation. Send the complete machine type, serial number and installed software level.
  2. Record capacity and workload. Include installed drive types, RAID layout and current usable space with peak IOPS and latency.
  3. Check rack and power. Record rail depth, service clearance and the existing outlet and PDU connections; include every expansion shelf.
  4. Plan attachment and migration. Include host adapters, switch models and optics with the available migration window.

FlashSystem 9600 technical references

FlashSystem 9600 product specifications and identifiers ... FlashSystem family specifications.

IBM FlashSystem 9600 5078-A40 feature and configuration details

Use these entries to match the chart’s identifiers to their exact configuration. Keep each capacity, connection and scale limit with its stated enclosure, software and system scope.

Maximum I/O ... 5078-A40

FlashSystem 9600 host and expansion connections

Configuration
Thirty-two ports

Understand this configuration and identifier before matching a replacement. Send the complete model and Maximum I/O entry with your configuration or parts request.

Parts and options for FlashSystem 9600

Match each option to the installed enclosure and software. An order feature, drive-model identifier and service FRU have different roles; the source context below stays with each number.

Memory

Published options for this model; send the installed identifier with a parts request.

FlashSystem 9600 memory options
Product Description Part numbers Feature codes Model note
Memory module 128 GB module in the dedicated parts list 078P8006 Total supported system memory is 1.5 to 3 TB; match installed module layout.

Memory module for 5078-A40

128 GB module in the dedicated parts list

Part numbers
078P8006

Total supported system memory is 1.5 to 3 TB; match installed module layout.

Match this memory option to the installed module arrangement. The capacity can describe one module or a complete kit; the description and model note retain that distinction.

Understand memory compatibility

Disk

Published options for this model; send the installed identifier with a parts request.

FlashSystem 9600 disk options
Product Description Part numbers Feature codes Model note
FCM5 Small 6.6 TB 03PM128 ADSJ
FCM5 Medium 13.2 TB 03PM131 ADSK
FCM5 Large 26.4 TB 03PM134 ADSL
FCM5 XL 52.8 TB 03PM137 ADSM
FCM5 XXL 105.6 TB, 9600-only in the 5600 source 03PM220 ADSN
Standard NVMe SSD 7.68 TB 03NK551 ADTK

FCM5 Small for 5078-A40

6.6 TB

Part numbers
03PM128
Feature codes
ADSJ

Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.

Understand disk compatibility

FCM5 Medium for 5078-A40

13.2 TB

Part numbers
03PM131
Feature codes
ADSK

Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.

Understand disk compatibility

FCM5 Large for 5078-A40

26.4 TB

Part numbers
03PM134
Feature codes
ADSL

Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.

Understand disk compatibility

FCM5 XL for 5078-A40

52.8 TB

Part numbers
03PM137
Feature codes
ADSM

Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.

Understand disk compatibility

FCM5 XXL for 5078-A40

105.6 TB, 9600-only in the 5600 source

Part numbers
03PM220
Feature codes
ADSN

Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.

Understand disk compatibility

Standard NVMe SSD for 5078-A40

7.68 TB

Part numbers
03NK551
Feature codes
ADTK

Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.

Understand disk compatibility

Adapters

Published options for this model; send the installed identifier with a parts request.

FlashSystem 9600 adapters options
Product Description Part numbers Feature codes Model note
Fibre Channel 32 Gb quad-port 03JK177
Fibre Channel 64 Gb quad-port 03JK911
Ethernet 100 / 40 Gb dual-port 03JN309
Ethernet 25 / 10 Gb quad-port 03NK184
Control enclosure 5078-A40 03LG971
Node canister 5078-A40 source context 03MT852
Power supply 5078-A40 source context 03NK500

Fibre Channel for 5078-A40

32 Gb quad-port

Part numbers
03JK177

Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.

Understand adapters compatibility

Fibre Channel for 5078-A40

64 Gb quad-port

Part numbers
03JK911

Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.

Understand adapters compatibility

Ethernet for 5078-A40

100 / 40 Gb dual-port

Part numbers
03JN309

Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.

Understand adapters compatibility

Ethernet for 5078-A40

25 / 10 Gb quad-port

Part numbers
03NK184

Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.

Understand adapters compatibility

Control enclosure for 5078-A40

5078-A40

Part numbers
03LG971

Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.

Understand adapters compatibility

Node canister for 5078-A40

5078-A40 source context

Part numbers
03MT852

Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.

Understand adapters compatibility

Power supply for 5078-A40

5078-A40 source context

Part numbers
03NK500

Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.

Understand adapters compatibility

Get a FlashSystem 9600 configuration or parts quote

Send us your installed model and the capacity or repair you need. We can match the controller, media and connections before quoting the complete configuration.

Request FlashSystem 9600 help