FlashSystem 7600 5075-A30 storage and upgrades

Consolidate demanding workloads on thirty-two FCM5 bays in 2U with the 7600. We can size cache and host adapters alongside capacity so the SAN can keep up with the storage.

Published bandwidth
Up to 55 GB/s
See the stated source and test context.
Published IOPS
4.3 million read hit
Control enclosure
2U
32 EDSFF NVMe
System cache
768 GB to 1.5 TB
On this FlashSystem 7600 page

FlashSystem 7600 specifications

FlashSystem 7600 enclosure and performance specifications
SpecificationModel detail
Machine type and model5075-A30
Control enclosure2U
Internal drive positions32 EDSFF NVMe
System cache / memory768 GB to 1.5 TB
Published IOPS4.3 million read hit
Published bandwidthUp to 55 GB/s
Capacity context1,689.6 TB nominal raw

Published maxima describe specific test conditions. Application results depend on the drive population and RAID layout as well as block size, read/write mix and host connections.

FlashSystem 7600 drive choices and capacity

FlashSystem 7600 storage media
Drive classSupported source context
FCM56.6 TB through 52.8 TB EDSFF
Standard EDSFF NVMe1.92 TB; 3.84 TB; 7.68 TB
Nominal installed raw32 x 52.8 TB = 1,689.6 TB before RAID and reserve

Raw capacity is the installed media total before RAID and reserves. Usable capacity is what remains for data; effective capacity also assumes compression or other data reduction.

FlashSystem 7600 host connectivity

FlashSystem 7600 host and expansion connections
ConnectionConfiguration
Fibre Channel32 / 64 Gb FC or FC-NVMe
Ethernet25 / 10 Gb or 100 / 40 Gb; iSCSI and NVMe/TCP
I/OFour adapter slots per node; up to thirty-two optional ports

FlashSystem 7600 expansion and scale

FlashSystem 7600 expansion scope
OptionModel or limit
FlashSystem GridApproximately 230 PBe at the stated data-reduction assumptions
Physical shelf supportNo direct SAS shelf option is identified for 5075-A30 in the dedicated source; use supported Grid or external-storage virtualization configurations

FlashSystem 7600 detailed hardware and feature tables

7600 performance and enclosure limits

7600 performance and enclosure limits
Performance / Scale CharacteristicIBM FlashSystem 7600 Maximum or Supported Specification
Machine Type / Model5075-A30
Maximum IOPSUp to 4.3 million 4K read-hit IOPS
Maximum BandwidthUp to 55 GB/s
Maximum Effective Capacity ... Single EnclosureUp to approximately 7.2 PBe based on IBM data-reduction assumptions
Maximum Effective Capacity ... FlashSystem GridUp to approximately 230 PBe
Control Enclosure2U
NVMe Drive Slots32 internal front-accessible EDSFF NVMe slots
FlashCore GenerationIBM FlashCore Module 5 (FCM5)
Largest FCM5 Capacity52.8 TB supported on FlashSystem 7600
Maximum Raw FCM Capacity1,689.6 TB using 32 × 52.8 TB FCM5 modules
Base System Memory768 GB total ... 384 GB per node canister
Maximum System Memory1.5 TB total ... 768 GB per node canister
Node Canisters2 active-active node canisters forming a redundant I/O Group
Adapter Slots4 adapter slots per node canister
Maximum I/O PortsUp to 32 optional I/O ports
Maximum Fibre Channel Speed64 Gb Fibre Channel / FC-NVMe
Maximum Ethernet Speed100 Gb Ethernet
Ethernet Storage ProtocolsiSCSI and NVMe/TCP; supported configurations also provide RDMA capabilities
Industry-Standard NVMe SSD Capacities1.92 TB, 3.84 TB and 7.68 TB EDSFF NVMe SSDs
Minimum IBM Storage Virtualize Level9.1.2

7600 FCM5 performance by module size

7600 FCM5 performance by module size
FCM5 CapacityRead BandwidthWrite Bandwidth16K Read IOPSEndurance
6.6 TBUp to approximately 2,200 MB/sUp to approximately 770 MB/sApproximately 125K1 DWPD
13.2 TBUp to approximately 2,500 MB/sUp to approximately 770 MB/sApproximately 150K1 DWPD
26.4 TBUp to approximately 3,500 MB/sUp to approximately 1,500 MB/sApproximately 200K1 DWPD
52.8 TBUp to approximately 3,500 MB/sUp to approximately 1,500 MB/sApproximately 200K1 DWPD

7600 matched-node memory configurations

7600 matched-node memory configurations
ConfigurationIBM Feature CodeDIMMs per NodeMemory per NodeTotal System Memory
BaseFactory Configuration6 × 64GB384GB768GB
Memory / Cache UpgradeALGG12 × 64GB768GB1.5TB

7600 64 Gb Fibre Channel adapter limits

7600 64 Gb Fibre Channel adapter limits
AdapterQuad-Port 64Gb Fibre Channel
Ports4 per adapter
Supported Speeds64Gb, 32Gb and 16Gb
ProtocolsSCSI over Fibre Channel and FC-NVMe
Maximum per Node3
Minimum SoftwareIBM Storage Virtualize 9.1.2
TransceiverShort-wave SFP supplied as standard

7600 32 Gb Fibre Channel adapter limits

7600 32 Gb Fibre Channel adapter limits
AdapterQuad-Port 32Gb Fibre Channel
Ports4 per adapter
ProtocolsSCSI over Fibre Channel and FC-NVMe
Maximum per Node4
Minimum SoftwareIBM Storage Virtualize 9.1.2

7600 Ethernet adapter options

7600 Ethernet adapter options
AdapterPortsSupported SpeedsPrimary Storage UsesMaximum per Node
Quad-Port Ethernet425Gb / 10GbiSCSI, NVMe/TCP, replication over TCP4
Dual-Port Ethernet2100Gb / 40GbiSCSI, NVMe/TCP, RDMA-assisted replication4

7600 host and scale limits

FlashSystem 7600 configuration limits and source differences

  • The current dedicated page gives 4.3 million read-hit IOPS while the broad overview gives 3.5 million. We use the dedicated model figure with its test scope.
  • Storage Virtualize 9.1.2 or later is required in the dedicated source.
  • The 7.2 PBe enclosure capacity assumes reducible data. The 1,689.6 TB installed-module calculation is before RAID.
  • Drive-model identifiers such as 1014072E are not automatically service FRUs.

FlashSystem 7600 software and IBM i attachment

We check the installed IBM Storage Virtualize or Spectrum Virtualize level against the proposed drives and adapters. Features such as replication, encryption and snapshots depend on the model, software level and entitlements.

For IBM i, send the Power model, IBM i release and host adapter details. We check direct or switched attachment and the supported protocol in the IBM System Storage Interoperation Center before finalizing the configuration.

FlashSystem 7600 data services and availability

  • Storage Virtualize 9.1.2 or later in the dedicated model specification.
  • FlashSystem Grid for supported workload movement and system modernization.
  • FCM5 computational-storage assistance for ransomware detection; this does not replace a recovery plan.

Room and upgrade requirements for FlashSystem 7600

  1. Identify the installation. Send the complete machine type, serial number and installed software level.
  2. Record capacity and workload. Include installed drive types, RAID layout and current usable space with peak IOPS and latency.
  3. Check rack and power. Record rail depth, service clearance and the existing outlet and PDU connections; include every expansion shelf.
  4. Plan attachment and migration. Include host adapters, switch models and optics with the available migration window.

FlashSystem 7600 technical references

FlashSystem 7600 product specifications and identifiers ... FlashSystem family specifications.

IBM FlashSystem 7600 5075-A30 feature and configuration details

Use these entries to match the chart’s identifiers to their exact configuration. Keep each capacity, connection and scale limit with its stated enclosure, software and system scope.

I/O ... 5075-A30

FlashSystem 7600 host and expansion connections

Configuration
Four adapter slots per node; up to thirty-two optional ports

Understand this configuration and identifier before matching a replacement. Send the complete model and I/O entry with your configuration or parts request.

NVMe Drive Slots ... 5075-A30

7600 performance and enclosure limits

IBM FlashSystem 7600 Maximum or Supported Specification
32 internal front-accessible EDSFF NVMe slots

Understand this configuration and identifier before matching a replacement. Send the complete model and NVMe Drive Slots entry with your configuration or parts request.

6.6 TB ... 5075-A30

7600 FCM5 performance by module size

Read Bandwidth
Up to approximately 2,200 MB/s
Write Bandwidth
Up to approximately 770 MB/s
16K Read IOPS
Approximately 125K
Endurance
1 DWPD

Understand this configuration and identifier before matching a replacement. Send the complete model and 6.6 TB entry with your configuration or parts request.

13.2 TB ... 5075-A30

7600 FCM5 performance by module size

Read Bandwidth
Up to approximately 2,500 MB/s
Write Bandwidth
Up to approximately 770 MB/s
16K Read IOPS
Approximately 150K
Endurance
1 DWPD

Understand this configuration and identifier before matching a replacement. Send the complete model and 13.2 TB entry with your configuration or parts request.

26.4 TB ... 5075-A30

7600 FCM5 performance by module size

Read Bandwidth
Up to approximately 3,500 MB/s
Write Bandwidth
Up to approximately 1,500 MB/s
16K Read IOPS
Approximately 200K
Endurance
1 DWPD

Understand this configuration and identifier before matching a replacement. Send the complete model and 26.4 TB entry with your configuration or parts request.

52.8 TB ... 5075-A30

7600 FCM5 performance by module size

Read Bandwidth
Up to approximately 3,500 MB/s
Write Bandwidth
Up to approximately 1,500 MB/s
16K Read IOPS
Approximately 200K
Endurance
1 DWPD

Understand this configuration and identifier before matching a replacement. Send the complete model and 52.8 TB entry with your configuration or parts request.

Base ... 5075-A30

7600 matched-node memory configurations

IBM Feature Code
Factory Configuration
DIMMs per Node
6 × 64GB
Memory per Node
384GB
Total System Memory
768GB

Understand this configuration and identifier before matching a replacement. Send the complete model and Base entry with your configuration or parts request.

Supported Speeds ... 5075-A30

7600 64 Gb Fibre Channel adapter limits

Quad-Port 64Gb Fibre Channel
64Gb, 32Gb and 16Gb

Understand this configuration and identifier before matching a replacement. Send the complete model and Supported Speeds entry with your configuration or parts request.

Maximum per Node ... 5075-A30

7600 64 Gb Fibre Channel adapter limits

Quad-Port 64Gb Fibre Channel
3

7600 32 Gb Fibre Channel adapter limits

Quad-Port 32Gb Fibre Channel
4

Understand this configuration and identifier before matching a replacement. Send the complete model and Maximum per Node entry with your configuration or parts request.

Parts and options for FlashSystem 7600

Match each option to the installed enclosure and software. An order feature, drive-model identifier and service FRU have different roles; the source context below stays with each number.

Memory

Published options for this model; send the installed identifier with a parts request.

FlashSystem 7600 memory options
Product Description Part numbers Feature codes Model note
Cache upgrade 768 GB per node, 1.5 TB total ALGG Ordering identifier 5075-ALGG.

Cache upgrade for 5075-A30

768 GB per node, 1.5 TB total

Feature codes
ALGG

Ordering identifier 5075-ALGG.

Match this memory option to the installed module arrangement. The capacity can describe one module or a complete kit; the description and model note retain that distinction.

Understand memory compatibility

Disk

Published options for this model; send the installed identifier with a parts request.

FlashSystem 7600 disk options
Product Description Part numbers Feature codes Model note
FCM5 Small 6.6 TB physical 1014072E IBM drive-model identifier; not asserted as a service FRU.
FCM5 Medium 13.2 TB physical 1014072F
FCM5 Large 26.4 TB physical 10140730
FCM5 XL 52.8 TB physical 10140731
Standard NVMe SSD 1.92 TB EDSFF 1014070D
Standard NVMe SSD 3.84 TB EDSFF 1014070E
Standard NVMe SSD 7.68 TB EDSFF 1014070F

FCM5 Small for 5075-A30

6.6 TB physical

Part numbers
1014072E

IBM drive-model identifier; not asserted as a service FRU.

Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.

Understand disk compatibility

FCM5 Medium for 5075-A30

13.2 TB physical

Part numbers
1014072F

Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.

Understand disk compatibility

FCM5 Large for 5075-A30

26.4 TB physical

Part numbers
10140730

Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.

Understand disk compatibility

FCM5 XL for 5075-A30

52.8 TB physical

Part numbers
10140731

Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.

Understand disk compatibility

Standard NVMe SSD for 5075-A30

1.92 TB EDSFF

Part numbers
1014070D

Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.

Understand disk compatibility

Standard NVMe SSD for 5075-A30

3.84 TB EDSFF

Part numbers
1014070E

Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.

Understand disk compatibility

Standard NVMe SSD for 5075-A30

7.68 TB EDSFF

Part numbers
1014070F

Match this storage option to the enclosure and carrier. Its listed capacity describes the drive or option; usable application space also depends on protection and the installed configuration.

Understand disk compatibility

Adapters

Published options for this model; send the installed identifier with a parts request.

FlashSystem 7600 adapters options
Product Description Part numbers Feature codes Model note
Fibre Channel Quad-port 64 Gb; maximum three adapters per node in source
Fibre Channel Quad-port 32 Gb; maximum four adapters per node in source
Ethernet Quad-port 25 / 10 Gb or dual-port 100 / 40 Gb

Fibre Channel for 5075-A30

Quad-port 64 Gb; maximum three adapters per node in source

Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.

Understand adapters compatibility

Fibre Channel for 5075-A30

Quad-port 32 Gb; maximum four adapters per node in source

Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.

Understand adapters compatibility

Ethernet for 5075-A30

Quad-port 25 / 10 Gb or dual-port 100 / 40 Gb

Match this connection option to the supported slot or attachment position. Keep its physical profile and connection type with the installed software and cabling requirements.

Understand adapters compatibility

Get a FlashSystem 7600 configuration or parts quote

Send us your installed model and the capacity or repair you need. We can match the controller, media and connections before quoting the complete configuration.

Request FlashSystem 7600 help