AS400 to IBM Power 11 Partners
(888) 682-5335

IBM FlashSystem 9500

FlashSystem 9500 4983-AH8 storage and upgrades

Consolidate large workloads on the 9500 with forty-eight NVMe bays and up to 3 TB of cache. We can match the 4983-AH8 ordering features to your installed enclosure and expansion plan.

Published bandwidth
Up to 45 GB/s
See the stated source and test context.
Published IOPS
2.5 million read miss
Control enclosure
4U
48 NVMe
System cache
1 / 2 / 3 TB
On this FlashSystem 9500 page

FlashSystem 9500 specifications

FlashSystem 9500 enclosure and performance specifications
SpecificationModel detail
Machine type and model4983-AH8; 4666-AH8 in family overview
Control enclosure4U
Internal drive positions48 NVMe
System cache / memory1 / 2 / 3 TB
Published IOPS2.5 million read miss
Published bandwidthUp to 45 GB/s, dedicated source
Capacity context1,843.2 TB nominal internal FCM

Published maxima describe specific test conditions. Application results depend on the drive population and RAID layout as well as block size, read/write mix and host connections.

FlashSystem 9500 drive choices and capacity

FlashSystem 9500 storage media
Drive classSupported source context
FCM3AHS9 / AHSA / AHSB / AHSC; 4.8 TB through 38.4 TB
FCM4AHSE / AHSF / AHSG / AHSH; 4.8 TB through 38.4 TB
Standard NVMeAHTH to AHTL; 1.92 TB through 30.72 TB
SCMAHTM 1.6 TB; up to twelve per I/O group in the source

Raw capacity is the installed media total before RAID and reserves. Usable capacity is what remains for data; effective capacity also assumes compression or other data reduction.

FlashSystem 9500 host connectivity

FlashSystem 9500 host and expansion connections
ConnectionConfiguration
Fibre ChannelAHBB 32 Gb or AHBK 64 Gb adapter pair
EthernetAHB8 100 Gb RoCE; AHBH 25 / 10 Gb RoCE; AHBJ 25 / 10 Gb iWARP
SASAHBA expansion attachment pair

FlashSystem 9500 expansion and scale

FlashSystem 9500 expansion scope
OptionModel or limit
SFF4983-AFF, twenty-four SAS SSD bays
High density4983-A9F, ninety-two SAS SSD bays
Two control enclosuresNinety-six internal NVMe drives; up to 464 total drives at applicable software levels

FlashSystem 9500 detailed hardware and feature tables

9500 dedicated model performance and maximums

9500 dedicated model performance and maximums
Performance / Maximum CharacteristicIBM FlashSystem 9500 4983-AH8 Specification
Maximum IOPSUp to approximately 2.5 million 4K read-miss IOPS per control enclosure
Minimum Published Read LatencyLess than approximately 50 microseconds under qualifying conditions
Maximum Read BandwidthUp to approximately 45GB/s per control enclosure
Control Enclosure4U
Processors4 Intel Xeon processors total, 24 cores each
Total Processor Cores96 cores per control enclosure
Node Canisters2 active-active node canisters per control enclosure
Base System MemoryApproximately 1TB
Maximum System MemoryApproximately 3TB per control enclosure
Maximum Memory per NodeApproximately 1.5TB
Internal NVMe Drive Slots48 per control enclosure
Maximum Control Enclosures per System2
Maximum Active Nodes4
Maximum Internal NVMe Drives96 with two control enclosures
Largest FCM3 / FCM4 Capacity38.4TB per FlashCore Module
Maximum Nominal Internal FCM Capacity ... One Enclosure1,843.2TB using 48 × 38.4TB FCMs
Maximum Nominal Internal FCM Capacity ... Two Enclosures3,686.4TB using 96 × 38.4TB FCMs
Maximum Total DrivesUp to 464 at applicable IBM Storage Virtualize levels
Maximum Expansion EnclosuresUp to 12 per two-control-enclosure system at applicable software levels
Maximum Fibre Channel Hosts2,048
Maximum Volume Mappings per Host2,048
Maximum Host Mappings per System64,000
Maximum NVMe/RDMA HostsUp to 512 per system at applicable software levels
Maximum NVMe/TCP HostsUp to 512 per system at applicable software levels
Maximum Managed StorageUp to 32PB
Maximum Individual Volume256TB
Maximum Fibre Channel Speed64Gb Fibre Channel
Maximum Ethernet Speed100Gb Ethernet
Maximum Remote Copy RelationshipsUp to 10,000
Maximum HyperSwap RelationshipsUp to 2,000

9500 FCM4 performance by module capacity

9500 FCM4 performance by module capacity
FCM4 CapacityApprox. Read BandwidthApprox. Write BandwidthApprox. 16K Read IOPSEndurance
4.8TBUp to approximately 2,200MB/sUp to approximately 750MB/sApproximately 150K1 DWPD
9.6TBUp to approximately 2,200MB/sUp to approximately 750MB/sApproximately 150K1 DWPD
19.2TBUp to approximately 3,500MB/sUp to approximately 1,500MB/sApproximately 200K1 DWPD
38.4TBUp to approximately 3,500MB/sUp to approximately 1,500MB/sApproximately 200K1 DWPD

9500 enterprise host limits

9500 enterprise host limits
Host Scale CharacteristicMaximum
Hosts per system2,048
Volume mappings per host2,048
Total host mappings64,000
NVMe/RDMA hosts per systemUp to approximately 512
NVMe/TCP hosts per systemUp to approximately 512

9500 Storage Virtualize scale limits

9500 Storage Virtualize scale limits
Storage Virtualize Scale CharacteristicMaximum at Applicable Software Levels
Managed disks4,096
Storage pools1,024
Total managed storageUp to 32PB
Maximum individual volume256TB
Remote Copy relationshipsUp to 10,000
HyperSwap relationshipsUp to 2,000
Data Reduction PoolsUp to 4

9500 standard NVMe feature codes

9500 standard NVMe feature codes
CapacityFeature CodeOrdering Identifier
1.92TBAHTH4983-AHTH
3.84TBAHTI4983-AHTI
7.68TBAHTJ4983-AHTJ
15.36TBAHTK4983-AHTK
30.72TBAHTL4983-AHTL

9500 optics and transceiver features

9500 optics and transceiver features
FeatureDescriptionRequires
ACHPFour 25Gb Ethernet short-wave SFP28 transceiversAHBH, AHBJ or applicable adapter
ACHQFour 10Gb Ethernet short-wave SFP+ transceiversAHBH, AHBJ or applicable adapter
ACHVPair of 32Gb Fibre Channel long-wave SFP transceiversAHBB
ACHXFour 100Gb Ethernet QSFP28 SR4 transceiversAHB8

9500 all-flash SAS expansion models

9500 all-flash SAS expansion models
IBM ModelDescriptionDrive BaysForm FactorInterface
4983-AFFFlashSystem 9500 SFF All-Flash Expansion with Expert Care242U12Gb SAS
4983-A9FFlashSystem 9500 High-Density All-Flash Expansion with Expert Care925U12Gb SAS

9500 SAS cable features

9500 SAS cable features
Feature CodeDescription
ACUA0.6m 12Gb SAS Cable ... SFF Expansion
ACUB1.5m 12Gb SAS Cable ... SFF Expansion
ACUC3m 12Gb SAS Cable ... SFF / High-Density Expansion
ACUD6m 12Gb SAS Cable ... SFF / High-Density Expansion

9500 encryption features

9500 encryption features
Feature CodeDescription
ACEEEncryption Enablement
ACEAEncryption USB Flash Drives ... Four Pack

FlashSystem 9500 configuration limits and source differences

  • The dedicated catalog identity is 4983-AH8. The family overview uses 4666-AH8 and one intermediate heading says 4983-4H8; the dedicated product identity controls this page.
  • The broad overview gives 8 million IOPS / 136 GB/s without the same test scope. This page uses the dedicated 2.5 million read-miss IOPS / 45 GB/s context.
  • The family overview lists FS9500R beside 9500. It does not establish a separate configured rack specification here.
  • FCM3 and FCM4 compatibility depends on code, firmware and array rules; a matching capacity does not prove interchangeability.

FlashSystem 9500 software and IBM i attachment

We check the installed IBM Storage Virtualize or Spectrum Virtualize level against the proposed drives and adapters. Features such as replication, encryption and snapshots depend on the model, software level and entitlements.

For IBM i, send the Power model, IBM i release and host adapter details. We check direct or switched attachment and the supported protocol in the IBM System Storage Interoperation Center before finalizing the configuration.

FlashSystem 9500 data services and availability

  • Storage Virtualize storage virtualization and supported two-control-enclosure scale-out.
  • Encryption enablement ACEE; encryption USB feature ACEA or a supported key-management configuration.
  • Remote Copy and HyperSwap relationship limits depend on the installed software level.

Room and upgrade requirements for FlashSystem 9500

  1. Identify the installation. Send the complete machine type, serial number and installed software level.
  2. Record capacity and workload. Include installed drive types, RAID layout and current usable space with peak IOPS and latency.
  3. Check rack and power. Record rail depth, service clearance and the existing outlet and PDU connections; include every expansion shelf.
  4. Plan attachment and migration. Include host adapters, switch models and optics with the available migration window.

FlashSystem 9500 technical references

FlashSystem 9500 product specifications and identifiers ... FlashSystem family specifications.

Parts and options for FlashSystem 9500

Match each option to the installed enclosure and software. An order feature, drive-model identifier and service FRU have different roles; the source context below stays with each number.

Memory

Published options for this model; send the installed identifier with a parts request.

FlashSystem 9500 memory options
Product Description Part numbers Feature codes Model note
Base cache Approximately 1 TB total ACGM Ordering identifier 4983-ACGM.
Cache upgrade Approximately 2 TB total ACGN
Maximum cache Approximately 3 TB total ACGP
Disk

Published options for this model; send the installed identifier with a parts request.

FlashSystem 9500 disk options
Product Description Part numbers Feature codes Model note
FCM3 4.8 TB 03JK076 AHS9
FCM3 9.6 TB 03JK077 AHSA
FCM4 4.8 TB 03JK992 AHSE
FCM4 9.6 TB 03LG001 AHSF
FCM4 19.2 TB 03LG010 AHSG
FCM4 38.4 TB 03LG019 AHSH
Adapters

Published options for this model; send the installed identifier with a parts request.

FlashSystem 9500 adapters options
Product Description Part numbers Feature codes Model note
FC adapter pair 32 Gb four-port per adapter AHBB 4983-AHBB ordering context.
FC adapter pair 64 Gb four-port per adapter AHBK
Ethernet adapter pair 100 Gb RoCE AHB8
SAS attachment pair 12 Gb AHBA

Get a FlashSystem 9500 configuration or parts quote

Send us your installed model and the capacity or repair you need. We can match the controller, media and connections before quoting the complete configuration.