Your current Power 9 model and Linux workload
Power 9 meets the RHEL 9 processor baseline but not the Power 10 baseline for RHEL 10 or SLES 16. Canonical supports Power 9 in Ubuntu 22.04 LTS and later eligible releases.
Choose the exact catalog identity below for its planning notes. The list identifies assessment starting points; eligibility still depends on the installed edition and configuration.
| Current model | Configuration question |
|---|---|
| AC922 8335-GTC | Keep accelerator dependencies with the application |
| AC922 8335-GTG | Keep accelerator dependencies with the application |
| AC922 8335-GTH | Keep accelerator dependencies with the application |
| AC922 8335-GTW | Keep accelerator dependencies with the application |
| AC922 8335-GTX | Keep accelerator dependencies with the application |
| E950 9040-MR9 | Size each partition and its storage connections |
| E980 9080-M9S | Size each partition and its storage connections |
| H922 9223-22H | Check the workload allocation and certification |
| H922S 9223-22S | Check the workload allocation and certification |
| H924 9223-42H | Check the workload allocation and certification |
| H924S 9223-42S | Check the workload allocation and certification |
| IC922 9183-22X | Keep accelerator dependencies with the application |
| L922 9008-22L | Identify the boot firmware and virtualization layer |
| LC921 9006-12P | Identify the boot firmware and virtualization layer |
| LC922 5104-22C | Identify the boot firmware and virtualization layer |
| LC922 9006-22C | Identify the boot firmware and virtualization layer |
| LC922 9006-22P | Identify the boot firmware and virtualization layer |
| S914 9009-41A | Match the capacity change to the actual bottleneck |
| S914 9009-41G | Match the capacity change to the actual bottleneck |
| S922 9009-22A | Match the capacity change to the actual bottleneck |
| S922 9009-22G | Match the capacity change to the actual bottleneck |
| S924 9009-42A | Match the capacity change to the actual bottleneck |
| S924 9009-42G | Match the capacity change to the actual bottleneck |
AC922 8335-GTC: keep accelerator dependencies with the application
Record GPU or accelerator features and their driver/runtime versions. Confirm whether the workload requires NVLink, a specific CUDA build or a certified analytics stack. A newer general-purpose Power server is not automatically an equivalent accelerator platform.
The catalog’s storage and I/O context is Confirm drive and accelerator carrier configuration. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
Choose the destination from the application or appliance certification first. Request a model comparison after the required accelerator and software combination has been established.
AC922 8335-GTC catalog details · Choose the installed-release branch · Prepare the migration inventory
AC922 8335-GTG: keep accelerator dependencies with the application
Record GPU or accelerator features and their driver/runtime versions. Confirm whether the workload requires NVLink, a specific CUDA build or a certified analytics stack. A newer general-purpose Power server is not automatically an equivalent accelerator platform.
The catalog’s storage and I/O context is Confirm drive and accelerator carrier configuration. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
Choose the destination from the application or appliance certification first. Request a model comparison after the required accelerator and software combination has been established.
AC922 8335-GTG catalog details · Choose the installed-release branch · Prepare the migration inventory
AC922 8335-GTH: keep accelerator dependencies with the application
Record GPU or accelerator features and their driver/runtime versions. Confirm whether the workload requires NVLink, a specific CUDA build or a certified analytics stack. A newer general-purpose Power server is not automatically an equivalent accelerator platform.
The catalog’s storage and I/O context is Two SFF drive bays with optional PCIe NVMe. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
Choose the destination from the application or appliance certification first. Request a model comparison after the required accelerator and software combination has been established.
AC922 8335-GTH catalog details · Choose the installed-release branch · Prepare the migration inventory
AC922 8335-GTW: keep accelerator dependencies with the application
Record GPU or accelerator features and their driver/runtime versions. Confirm whether the workload requires NVLink, a specific CUDA build or a certified analytics stack. A newer general-purpose Power server is not automatically an equivalent accelerator platform.
The catalog’s storage and I/O context is Confirm drive and accelerator carrier configuration. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
Choose the destination from the application or appliance certification first. Request a model comparison after the required accelerator and software combination has been established.
AC922 8335-GTW catalog details · Choose the installed-release branch · Prepare the migration inventory
AC922 8335-GTX: keep accelerator dependencies with the application
Record GPU or accelerator features and their driver/runtime versions. Confirm whether the workload requires NVLink, a specific CUDA build or a certified analytics stack. A newer general-purpose Power server is not automatically an equivalent accelerator platform.
The catalog’s storage and I/O context is Two SFF drive bays with optional PCIe NVMe. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
Choose the destination from the application or appliance certification first. Request a model comparison after the required accelerator and software combination has been established.
AC922 8335-GTX catalog details · Choose the installed-release branch · Prepare the migration inventory
E950 9040-MR9: size each partition and its storage connections
Capture the busy periods and resource allocation for each logical partition. Review external storage, multipath software and management-console levels. A consolidation plan must retain the isolation and recovery behavior the applications need.
The catalog’s storage and I/O context is Enterprise storage and I/O drawers; confirm the installed topology. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review E1050 9043-MRX and E1150 9043-MRU. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
E950 9040-MR9 catalog details · Choose the installed-release branch · Prepare the migration inventory
E980 9080-M9S: size each partition and its storage connections
Capture the busy periods and resource allocation for each logical partition. Review external storage, multipath software and management-console levels. A consolidation plan must retain the isolation and recovery behavior the applications need.
The catalog’s storage and I/O context is Storage and I/O scale with node and drawer topology. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review E1050 9043-MRX and E1150 9043-MRU. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
E980 9080-M9S catalog details · Choose the installed-release branch · Prepare the migration inventory
H922 9223-22H: check the workload allocation and certification
Keep model-specific allocation limits beside the applications that use the server. For SAP or other certified software, confirm the exact application, database and OS combination. A compatible Linux or AIX kernel is only one part of that check.
The catalog’s storage and I/O context is SAS and NVMe options; confirm installed backplane. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
H922 9223-22H catalog details · Choose the installed-release branch · Prepare the migration inventory
H922S 9223-22S: check the workload allocation and certification
Keep model-specific allocation limits beside the applications that use the server. For SAP or other certified software, confirm the exact application, database and OS combination. A compatible Linux or AIX kernel is only one part of that check.
The catalog’s storage and I/O context is SAS and NVMe options; confirm installed backplane. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
H922S 9223-22S catalog details · Choose the installed-release branch · Prepare the migration inventory
H924 9223-42H: check the workload allocation and certification
Keep model-specific allocation limits beside the applications that use the server. For SAP or other certified software, confirm the exact application, database and OS combination. A compatible Linux or AIX kernel is only one part of that check.
The catalog’s storage and I/O context is SAS and NVMe options; confirm installed backplane. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
H924 9223-42H catalog details · Choose the installed-release branch · Prepare the migration inventory
H924S 9223-42S: check the workload allocation and certification
Keep model-specific allocation limits beside the applications that use the server. For SAP or other certified software, confirm the exact application, database and OS combination. A compatible Linux or AIX kernel is only one part of that check.
The catalog’s storage and I/O context is SAS plus supported U.2 NVMe options. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
H924S 9223-42S catalog details · Choose the installed-release branch · Prepare the migration inventory
IC922 9183-22X: keep accelerator dependencies with the application
Record GPU or accelerator features and their driver/runtime versions. Confirm whether the workload requires NVLink, a specific CUDA build or a certified analytics stack. A newer general-purpose Power server is not automatically an equivalent accelerator platform.
The catalog’s storage and I/O context is Linux server storage; confirm carrier, controller, and sector format. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
Choose the destination from the application or appliance certification first. Request a model comparison after the required accelerator and software combination has been established.
IC922 9183-22X catalog details · Choose the installed-release branch · Prepare the migration inventory
L922 9008-22L: identify the boot firmware and virtualization layer
Record whether the host uses OPAL, KVM, PowerVM or another documented arrangement. A PowerVM partition restore and a bare-metal or KVM installation use different boot and device assumptions.
The catalog’s storage and I/O context is Eight SFF bays with backplane and expansion options. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
L922 9008-22L catalog details · Choose the installed-release branch · Prepare the migration inventory
LC921 9006-12P: identify the boot firmware and virtualization layer
Record whether the host uses OPAL, KVM, PowerVM or another documented arrangement. A PowerVM partition restore and a bare-metal or KVM installation use different boot and device assumptions.
The catalog’s storage and I/O context is Four SAS or SATA bays plus four front NVMe bays. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
LC921 9006-12P catalog details · Choose the installed-release branch · Prepare the migration inventory
LC922 5104-22C: identify the boot firmware and virtualization layer
Record whether the host uses OPAL, KVM, PowerVM or another documented arrangement. A PowerVM partition restore and a bare-metal or KVM installation use different boot and device assumptions.
The catalog’s storage and I/O context is Confirm from installed backplane and carrier. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
LC922 5104-22C catalog details · Choose the installed-release branch · Prepare the migration inventory
LC922 9006-22C: identify the boot firmware and virtualization layer
Record whether the host uses OPAL, KVM, PowerVM or another documented arrangement. A PowerVM partition restore and a bare-metal or KVM installation use different boot and device assumptions.
The catalog’s storage and I/O context is Confirm from installed backplane and carrier. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
LC922 9006-22C catalog details · Choose the installed-release branch · Prepare the migration inventory
LC922 9006-22P: identify the boot firmware and virtualization layer
Record whether the host uses OPAL, KVM, PowerVM or another documented arrangement. A PowerVM partition restore and a bare-metal or KVM installation use different boot and device assumptions.
The catalog’s storage and I/O context is 12 SAS or SATA bays plus four front NVMe bays. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
LC922 9006-22P catalog details · Choose the installed-release branch · Prepare the migration inventory
S914 9009-41A: match the capacity change to the actual bottleneck
Compare processor use, memory pressure and storage response before choosing an upgrade. Record the installed processor feature and attached devices so the quote addresses the current workload rather than the model’s maximum specification.
The catalog’s storage and I/O context is SAS backplane options; capacity depends on processor and backplane. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
S914 9009-41A catalog details · Choose the installed-release branch · Prepare the migration inventory
S914 9009-41G: match the capacity change to the actual bottleneck
Compare processor use, memory pressure and storage response before choosing an upgrade. Record the installed processor feature and attached devices so the quote addresses the current workload rather than the model’s maximum specification.
The catalog’s storage and I/O context is SAS and U.2 NVMe options; confirm the installed backplane. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
S914 9009-41G catalog details · Choose the installed-release branch · Prepare the migration inventory
S922 9009-22A: match the capacity change to the actual bottleneck
Compare processor use, memory pressure and storage response before choosing an upgrade. Record the installed processor feature and attached devices so the quote addresses the current workload rather than the model’s maximum specification.
The catalog’s storage and I/O context is Eight SFF bays with backplane and expansion options. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
S922 9009-22A catalog details · Choose the installed-release branch · Prepare the migration inventory
S922 9009-22G: match the capacity change to the actual bottleneck
Compare processor use, memory pressure and storage response before choosing an upgrade. Record the installed processor feature and attached devices so the quote addresses the current workload rather than the model’s maximum specification.
The catalog’s storage and I/O context is SAS plus up to 14 NVMe devices, subject to configuration. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
S922 9009-22G catalog details · Choose the installed-release branch · Prepare the migration inventory
S924 9009-42A: match the capacity change to the actual bottleneck
Compare processor use, memory pressure and storage response before choosing an upgrade. Record the installed processor feature and attached devices so the quote addresses the current workload rather than the model’s maximum specification.
The catalog’s storage and I/O context is 12 or 18 SFF SAS bays with storage and expansion options. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
S924 9009-42A catalog details · Choose the installed-release branch · Prepare the migration inventory
S924 9009-42G: match the capacity change to the actual bottleneck
Compare processor use, memory pressure and storage response before choosing an upgrade. Record the installed processor feature and attached devices so the quote addresses the current workload rather than the model’s maximum specification.
The catalog’s storage and I/O context is SAS plus up to 14 NVMe devices, subject to configuration. Check the installed adapters and recovery devices against the destination; their presence on the source does not establish reuse eligibility.
Record the distribution’s full release and the output of uname -m. Then match the package architecture and boot arrangement to the Power Linux architecture guide.
For a replacement comparison, review L1022 9786-22H and L1122 9856-22H. Size and qualify the proposed configuration against this workload; these are candidates rather than guaranteed equivalents.
S924 9009-42G catalog details · Choose the installed-release branch · Prepare the migration inventory
Your installed Linux release on Power 9
Separate PowerVM servers from OpenPOWER, accelerator and Linux-only variants. The target’s boot firmware, hypervisor and application certification still control.
| Installed release or architecture | Planning next step |
|---|---|
| RHEL 7 | Review the exact source release and hardware requirements before selecting the target. This branch is an assessment topic, not confirmation that every listed model runs the release. |
| RHEL 8 | Review the exact source release and hardware requirements before selecting the target. This branch is an assessment topic, not confirmation that every listed model runs the release. |
| RHEL 9 | Review the exact source release and hardware requirements before selecting the target. This branch is an assessment topic, not confirmation that every listed model runs the release. |
| SLES 15 | Review the exact source release and hardware requirements before selecting the target. This branch is an assessment topic, not confirmation that every listed model runs the release. |
| Ubuntu LTS | Review the exact source release and hardware requirements before selecting the target. This branch is an assessment topic, not confirmation that every listed model runs the release. |
| ppc64, ppc64le and byte order | Review the exact source release and hardware requirements before selecting the target. This branch is an assessment topic, not confirmation that every listed model runs the release. |
Upgrade Linux or add capacity on Power 9
Start with the application result you need. A supported OS change can keep the existing server useful; a capacity change can address resource pressure. Neither establishes a supported release on hardware the vendor excludes.
- Compare processor allocations with measured Linux workload demand.
- Review memory capacity separately from processor demand.
- Review the Linux release guide for the installed level and desired destination.
- Ask Midland to compare an OS/capacity upgrade with replacement.
Migration from your Power 9 Linux system
Moving to another server is a separate task from updating the OS. The plan must qualify the destination, transfer the workload and prove the application works before the final switch.
- Record the source configuration.
- Choose a compatible transfer method.
- Rehearse application recovery and acceptance.
- Agree the rollback decision before new production transactions begin.
Sources and release checks
Guidance checked October 21, 2026. Midland catalog identities stay with their exact model. Hardware eligibility, software maintenance and application certification need separate checks for the installed configuration.